titleRequirements
  • Be able to open doors by special code - doors will remain open unitl deactivation code will be used
  • While time profile is used - Activation / deactivation code does not have any effect
  • While time profile is used - user can access the building and can also use their access methods - intercom will signalize that the doors are open only - door remain open until the time profile is active
  • While Activation code is used - doors are open until the deactivation code is used or activation timeout expire
  • While activation code is used - user can access by using any access method -  intercom will signalize that the doors are open only - door remains open the deactivation code is used or activation timeout expire
  • While activation code is not used - user can use any access method and the door remains open based on delay object in automation (default value is 5s) and will be clsoed after the timeout 

...

Settings prerequisities:

It is necessary to associate switch with the bluetooth, RFID reader or finger print modules in case that  these access method will be used. In this example Bluetooth module is used and it is necessary to associate moduel to a specific switch. In this example switch 1 is used.

...

Switch 2 is sued to control the output. Notice that the switch mode is in Bistable mode - this is crucial to ensure that the switch 2 remains activated during the time specified in the automation function. If the time profile needs to be used, it has to be applied on the switch 2.

 

Automation function

 

How it works:

  1. If the 666 code is entered - Switch 2 will be activated, delay for 50s will be activated. This delay can be modified and  determines the time during which the switch 2 will be active. Also FlipFlopRS is set to 1 to save the info that code 666 has been used. Once the timeout expire, Switch 2 is deactivated if the time profile is not active. HTTP command with reset keyword is send to reset FlipFlopRS to 0. Switch 2 deactivation related to 666 activation code is highlighted on the picture as object with ID 1. 
  2. If code 777 is used - the switch 2 is deactivated if the time profile is not active and HTTP command to loopback address is send with the keyword reset - this will reset FlipFlopRS to 0.
  3. If any access method associated with switch 1 is used - the switch 1 will send the HTTP command with the keyword: open. Based on this keyword, the switch 2 is activated and after 5s time out the switch 2 is deactivated if the condition is met. Switch 2 deactivation is highlighted on the picture as object with ID 2.  

...