skryty nazev, kvuli tomu, ze se dost casto opakuje nadpis faq a pod nim uplne stejny nazev

If the unit reboots after lock activation then check

  • If it is DC lock, then check the polarity of connected lock.
  • Check that lock parameters are respecting output values:
    • 2N® Helios IP Force, 2N® Helios IP Safety
      • Passive switch – NO and NC contacts, up to 30V/1A AC/DC
      • Active switch output – 9 up to 13 V DC depending on power supply (PoE: 9 V; adaptor: power supply voltage minus 1V), max 700mA
    • 2N® Helios IP Vario
      • Passive switch – NO and NC contacts, up to 30V/1A AC/DC
      • Active switch output – 10 up to 14 V DC depending on power supply (PoE: approx. 14 V; adaptor: same voltage as power supply), max 700mA
    • 2N® Helios IP UNI
      • Passive switch – NO and NC contacts, up to 30V/1A AC/DC
      • Active switch output – 8 up to 12 V DC depending on power supply (PoE: 9 V; adaptor: power supply voltage minus 2V), max 500mA